What does P err mean on a Hunter sprinkler system?

What does P err mean on a Hunter sprinkler system? CAUSE – The “P ERR” message is displayed when the P/MV circuit is drawing too much current. Common causes include; a defective solenoid on the

What does P err mean on a Hunter sprinkler system?

CAUSE – The “P ERR” message is displayed when the P/MV circuit is drawing too much current. Common causes include; a defective solenoid on the master valve, incompatible or defective pump relay, or wire run too long between the relay and controller.

What does err mean on sprinkler system?

Err indicates that a station has faulted due to a short on that output. Common reasons for this station fault include: 1) a defective solenoid, 2) defective field wiring, or 3) poor wire connections. STEP 1: Verify Station Fault. Remove the field wire for the faulted station.

How do I reset my hunter water system?

Resetting a Hunter X-Core is easy. To reset the irrigation controller, all you need to do is press the negative, the hand and the program keys at the same time, then use a small tool to press in the small reset button on the side of your controller. A small screwdriver or a pen will do the trick.

Why does my hunter sprinkler system keep running?

A common reason for a controller to repeat a cycle is too many programmed start times. Only one start time per active program is required, a second start time will cycle the program an additional time. NOTE: In the Start Times dial position, the numbers 1-4 do not represent stations.

How do I know if my sprinkler controller is bad?

Sprinkler System Troubleshooting — 5 Signs Of A Faulty System

  1. Controller Isn’t Working Properly.
  2. Low or High Water Pressure.
  3. Sprinkler is Stuck or Won’t Come Up.
  4. Puddles on Lawn or Around Sprinkler.
  5. Uneven Spray Patterns.
  6. When to Call a Professional.

How do I reset my hunter X2 sprinkler?

X2 – Total Reset

  1. Turn the dial to the RUN position.
  2. Press and hold the program button.
  3. Press and release the RESET button located inside the lower wiring compartment.
  4. When the display reads the controller station count; (e.g. 14) then DONE, release the PRG button.

What does P err stand for on Hunter Pro-C?

The display reads “P ERR”. Faulty pump relay or master valve wiring. Incompatible or defective relay of solenoid. Under sized wire to the pump or master valve. Check the master valve or pump start wire for continuity. Replace or repair the shorted wire.

What do the error messages on a hunter controller mean?

Common Controller Error Messages Hunter controllers incorporate automatic self-diagnostics that display the following error messages when electrical faults occur: • Err- indicates problems with SmartPort™wiring • # Err- indicates the station number for the shorted station(s) • P Err- indicates a high current draw on the P/MV circuit

What does err stand for on Hunter sprinkler system?

The display reads a station number and ERR, such as “2 ERR”. Short in valve wiring circuit, or faulty solenoid on the station number indicated. Check wire circuit or solenoid for the valve number indicated. repair short or replace solenoid. Press any button to clear the “ERR” from the display.

Why do I get A P err message?

CAUSE – The “P ERR” message is displayed when the P/MV circuit is drawing too much current. Common causes include; a defective solenoid on the master valve, incompatible or defective pump relay, or wire run too long between the relay and controller.