Does ductwork need to be fire rated?

Does ductwork need to be fire rated? Traditionally, all ductwork used to be fabricated from steel. It required being encased in a fire protection system when passing through a compartment wall or floor without the

Does ductwork need to be fire rated?

Traditionally, all ductwork used to be fabricated from steel. It required being encased in a fire protection system when passing through a compartment wall or floor without the aid of a fire damper, or when used as part of a smoke extraction system.

What are fire rated ducts?

Fire rated ductworks are used to guarantee the fire compartmentation. More precisely, fire rated ventilation ducts can avoid fire and heat spread between two compartments.

What temperature is fire rated ductwork tested to?

Fire rated insulation ensures that the temperature measured (outside in Type A, and inside in Type B) does not exceed 140°C mean average above ambient during the test and is deemed automatically failed if any thermocouple rises to 180°C.

Is flexible duct fire rated?

This is a 100mm / 4 inch diameter 6m flexible ducting ideal for high, medium, and low pressure ventilation and air conditioning systems. Suitable for high, medium and low pressure applications. Fire resistant: Complies with the requirements of BS476. Suitable for air conditioning and fume extraction systems.

Can a duct penetrate a fire wall?

The duct shall not terminate at a wall register in the fire-resistance-rated wall. Such walls are penetrated by ducted HVAC systems, have a required fire-resistance rating of 1 hour or less, and are in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3. 1.1 or 903.3. 1.2.

Where is fire rated ductwork used?

Other relevant applications

  • HVAC Insulation. HVAC insulation reduces energy loss for central heating systems, piping and ventilation ducts in large constructions.
  • External Wall Insulation.
  • Internal Wall Insulation.
  • Roof Insulation.
  • Floor Insulation.
  • Ceiling Insulation.

What is a fire and smoke damper?

Smoke dampers are passive fire protection products used in air conditioning and ventilation ductwork or installed in physical smoke barriers (e.g., walls). Smoke dampers can be activated by the fire alarm system, usually initiated by smoke detectors, or interlocked with a fire suppression system.

What does ductwork usually require for fire resistance properties?

Fire-resisting ducts are required to have a minimum fire resistance of 30 minutes (integrity).

What is insulated flexible duct used for?

What is Flexible Insulated Duct? A flexible, tubular passage for supply, return and exhaust air used in heating, ventilation and air conditioning systems. It can replace galvanized pipe and helps reduce heating and cooling loss as well as condensation build-up.